Which specific intrauterine contraceptive device has the lowest failure rate of about 0.1 per 100 women years?
সমাধান
সঠিক উত্তর: Option A
English Explanation
The correct answer is LNG-IUS (Levonorgestrel-Intrauterine System) or LNG 20 because it is a highly effective hormone-releasing IUD with the lowest failure rate among intrauterine devices, which is approximately 0.1 per 100 women years . It works by releasing 20 µg of levonorgestrel daily, which induces strong and uniform suppression of the endometrium and produces very scanty cervical mucus to prevent fertilization . In contrast, Copper T 380A has a failure rate of 0.8 per 100 women years . Multiload Cu 375 and the non-medicated Lippes loop have relatively higher failure rates and lack the added non-contraceptive benefits of third-generation IUDs .
বাংলা ব্যাখ্যা
সঠিক উত্তরটি হলো LNG-IUS (Levonorgestrel-Intrauterine System) বা LNG 20 কারণ এটি একটি অত্যন্ত কার্যকর hormone-releasing IUD যার failure rate হলো মাত্র 0.1 per 100 women years । এটি প্রতিদিন 20 µg levonorgestrel রিলিজ করে যা endometrium-কে uniform ভাবে suppress করে এবং cervical mucus-কে অত্যন্ত scanty করে দেয় । অন্যদিকে, Copper T 380A-এর failure rate হলো 0.8 per 100 women years । Multiload Cu 375 এবং Lippes loop-এর failure rate আরও বেশি এবং এগুলোতে third-generation IUDs-এর মতো অতিরিক্ত সুবিধাসমূহ নেই ।
BCS High Yield Points
- Failure rate of LNG 20 (LNG-IUS) is 0.1 and Cu T 380A is 0.8 per 100 women years .
- LNG-IUS releases 20 µg of levonorgestrel per day and its effective lifespan is 5-7 years .
- Cu T 380A has a lifespan of 10 years and carries a total 380 mm2 surface area of copper .
- Non-contraceptive benefits of LNG-IUS include the treatment of menorrhagia, dysmenorrhea, adenomyosis, and endometriosis .
- Lippes loop is a non-medicated open intrauterine device which is no longer commonly used .
Source: Textbook of Gynecology
The correct answer is LNG-IUS (Levonorgestrel-Intrauterine System) or LNG 20 because it is a highly effective hormone-releasing IUD with the lowest failure rate among intrauterine devices, which is approximately 0.1 per 100 women years . It works by releasing 20 µg of levonorgestrel daily, which induces strong and uniform suppression of the endometrium and produces very scanty cervical mucus to prevent fertilization . In contrast, Copper T 380A has a failure rate of 0.8 per 100 women years . Multiload Cu 375 and the non-medicated Lippes loop have relatively higher failure rates and lack the added non-contraceptive benefits of third-generation IUDs .
বাংলা ব্যাখ্যা
সঠিক উত্তরটি হলো LNG-IUS (Levonorgestrel-Intrauterine System) বা LNG 20 কারণ এটি একটি অত্যন্ত কার্যকর hormone-releasing IUD যার failure rate হলো মাত্র 0.1 per 100 women years । এটি প্রতিদিন 20 µg levonorgestrel রিলিজ করে যা endometrium-কে uniform ভাবে suppress করে এবং cervical mucus-কে অত্যন্ত scanty করে দেয় । অন্যদিকে, Copper T 380A-এর failure rate হলো 0.8 per 100 women years । Multiload Cu 375 এবং Lippes loop-এর failure rate আরও বেশি এবং এগুলোতে third-generation IUDs-এর মতো অতিরিক্ত সুবিধাসমূহ নেই ।
BCS High Yield Points
- Failure rate of LNG 20 (LNG-IUS) is 0.1 and Cu T 380A is 0.8 per 100 women years .
- LNG-IUS releases 20 µg of levonorgestrel per day and its effective lifespan is 5-7 years .
- Cu T 380A has a lifespan of 10 years and carries a total 380 mm2 surface area of copper .
- Non-contraceptive benefits of LNG-IUS include the treatment of menorrhagia, dysmenorrhea, adenomyosis, and endometriosis .
- Lippes loop is a non-medicated open intrauterine device which is no longer commonly used .
Source: Textbook of Gynecology